Valve Actuation
                                
                                
                                    Solenoid - Direct Acting
                                
                             
                            
                            
                                
                                    Media
                                
                                
                                    Air, Inert Gas; Water
                                
                             
                            
                                
                                    Pipe / Port Size
                                
                                
                                    1/2 "; 3/8 "; 3/4 "; 1 "
                                
                             
                            
                            
                                
                                    Function
                                
                                
                                    3 way - 3/2 Normally Closed; 3 way - 3/2 Normally Open
                                
                             
                            
                                
                                    Flow
                                
                                
                                    From 2.0 Cv to 6.0 Cv; From 6.0 Cv to 14.0 Cv
                                
                             
                            
                                
                                    Voltage
                                
                                
                                    100 to 240 AC/DC Voltage Ranging; 12 to 24 DC Voltage Ranging; 125 DC Battery Charging; 110 AC; 12 DC; 120 AC; 120 DC; 24 AC; 24 DC; 24 to 120 AC/DC Voltage Ranging; 250 DC Battery Charging; 240 - 50; 50/60; 60
                                
                             
                            
                                
                                    Operating Environment
                                
                                
                                    Hazardous; Indoor; Outdoor
                                
                             
                            
                                
                                    Standards / Regulations
                                
                                
                                    ATEX Zone 0-20; Class I Div 1; Class I Div 2; CSA; IEC Ex Zone 0-20; SIL; Type 1; Type 2; Type 3; Type 3S; Type 4; Type 4X; Type 6; Type 6P; Type 7; Type 9; UL